Professional 2-Port Remote Power Switch - Web Control With Auto Ping Support
Product Description
Professional 2-Port Remote Power Switch - Web Control
This premium power controller system is a network-controlled power switch provides remote and
central management of AC power distribution through LAN, WAN, or internet.
It is designed with versatile functions such as distant power reboot, equipment power on/off control, web/network administration, power event scheduling, power event alerts.
Other benefits from employing this intelligent power distribution system including:
- reduction of server/data center downtime and labor costs with remote power control.
- remote power source management/monitoring and power cycling of crashed systems through auto-ping setup
- setup of power event alert message sent through emails, SMS text messages or SNMP trap notification
- avoids power surges and UPS overloads by controlling power-on and power-off sequences.
- auto-reboot the failed network devices through auto-ping setup
Administrators can control network devices or power equipments from any locations within local network or internet and saves trips of technical personnel.
Eliminate service calls, system blackout down time and increase reliability.
Independent Control of Power Ports
Each AC power outlet can be independently powered on, off or power cycle for a immediate reboot,
time-delayed reboot and power event scheduling.
Users can have complete control over when and how powered equipments are restored with a timed delay or scheduled for On/Off shutdowns to conserve energy in the data center.
Designed for high voltage resistance and protection for leakage of electrical currency with 12.0 Amp total max current output.
Web Control Operation
Its intuitive web control panel provides various important power control functions including remote power scheduling, remote power setting and remote power status report, which can all be accessed via internet or local network:
- Advanced Power Operation Scheduling
This unit can perform power operation at any specific moment or on daily, weekly, monthly or yearly basis. For instance, users can program the connected power device to be turned on/off or rebooted performed daily at 11:00 AM, weekly on every Sunday at 7:00PM or yearly with specific month, day and time programmed in advanced. - Auto Ping For Automatic Reboot Of Crashed
Systems
The auto-ping function will automatically check the monitored network device's IP address periodically or any public domain address such as 4:4:4:4. Once the network equipment failing to respond the ping request over the user-defined event counts and preset time period, the programmed power action will be executed, which can be a timed reboot and alert email sent. - Secure User Access Control
This intelligent power switch supports multiple users access with password security. Manager can assign permissions for each user to access all or only the power outlets assigned. - IP/Mac Filter Protection
This unit also supports firewall function by providing both IP and MAC address filters to prevent unauthorized user from gaining access to the switch and devices connected through the network.
Screenshot 1 For Main Web Control Panel |
Screenshot 2 For Powered Device Monitoring |
Screenshot 3 For Power Operation Scheduling |
Screenshot 4 For Safety Shutdown Setup |
Screenshot 5 For Network Setup |
Screenshot 6 For Mail Server Setup |
Screenshot 7 For SMS Server Setup |
Screenshot 8 For SNMP TRAP Setup |
Screenshot 9 For System Setup - Others |
Arrange Power-Up Or Shutdown Sequence With Timed Delay
Supports power cycling sequence with priority so each power outlet can be turned on/off or rebooted with timed delay in seconds or minutes to prevent all power devices from starting up simultaneously to cause sudden overloading or dropped loads.
Screenshot For Power Sequence With Timed Delay |
Multiple
Safety Self-Protection
This intelligent power switch provides 2 different system shutdowns for
safety measure:
-
Auto Shutdown By Current Overload
This remote power switch has a circuit breaker built in for protection of devices connected to the power switch. This remote power switch will be automatically shut down for responding to a current overload or short circuit condition. -
Manual Shutdown By On/Off Power Button
A master power on/off button on the switch box itself for local operator to override the remote control mode and take control of this power switch in an emergency. No need to unplug the power cord or run to trip a breaker from the power panel.
Screenshot For Power Event Log |
Power Event Alert Notification
Warning alerts can be programmed to be sent out right after critical power conditions occur so manager can take preventive measures if needed.
The alert message can be generated automatically via emails, SMS text messages or SNMP trap notification according to the pre-set conditions.
Administrator can also check the operation events and warning events. The event log can be viewed directly or archived by downloading from the web page in .csv file format and saved into the hard drive.
Screenshot For Power Event Log |
Equipment Protection / Energy Savings
Protect sensitive devices or valuable equipment by keeping them powered off when not in use.
Great for energy related or network application by powering down equipments when not needed for power savings and to save on wear and tear or powering up environmental system.
1U Rack Mount Ready
This 2-port remote power switch is 1U rack mount ready. The rack mounting
ears are sold separately. User can mount this equipment on a standard
19" rack by purchasing the optional rack mounting ears from us.
- Professional IP-addressable power distribution unit with built-in web server with 2 AC outlets.
- Remote and central management of AC power distribution through LAN or WAN /Internet.
- All power outlets can be independently controlled locally and remotely.
- AC outlets from the power switch can be turned on/off, power cycled for a immediate reboot or reboot with a timed delay, power cycle sequence with assigned priority and power event scheduling.
- Complete power control via web, network or manual On/Off button on the front panel.
- Easy web scheduling for power operations performed on specific outlet daily, weekly, monthly and yearly.
- Supports API functions, HTTP commands for engineer to develop customized power management applications and build integration with other programs.
- Manual power on/off button to override the existing power status and gain immediate control from local access.
- LED displays for power status, total current and control mode indication.
- Supports power-up sequencing priority so power equipments can be started up properly in arranged way to prevent sudden overloading
- Supports Wake-On-LAN protocol for remotely starting up computers.
- Supports software safe shutdown function. Terminating running applications before powering off the computers or data servers.
- Featured with Auto-Ping function for detecting any failed network equipment and perform a timed reboot or other power control function.
- IP filter/mask security function with multi-users access management helps manage user privileges and prevent unauthorized access.
- Early warning alert sent by email, SMS text message or SNMP Trap to notify authorized personnel.
- 12-AMP circuit breaker protection to avoid power overload and protect connected devices.
- 1U rack mount ready. User can easily mount this equipment on a standard 19" rack by purchasing the optional rack mounting ears.
- Designed for high voltage resistance and protection for leakage of electrical currency.
- Network Interface: Ethernet RJ45 port x 1
- AC Power Outlet Plug: 3-Prong US style in NEMA-15R x 2
- Power Protection: 12-Amp circuit breaker
- LED Indicators:
- On/Off Status: 2 Green LEDs for each AC outlet
- Operation Status: 1 Green LED for LAN mode
- Network
Protocol Support:
- Supports TCP/IP, UDP, SNMP, DDNS, SNTP and HTTP protocols.
- Web GUI control through LAN/WAN network.
- NTP (Network Time Protocol )
- DHCP and alternate ports for web access
- Security password identification
- Input Power Voltage Range: AC 85-264V,47-63Hz
- Power Source Frequency: 50 ~ 60Hz
- Max
Rated Current Output:
- 12.0 Amp max total for both outlets.
- 8.0 Amp max per each power outlet.
- Operating Temperature Range: 32-140 degree F
- Dimension: 153 x 123 x 44 mm (W x D x H)
- Power Consumption: 5W
- Remote power switch unit
- AC power cord x 1
- Manual/Utility CD disk
For API documentation download, please click the following download icon to retrieve the API pdf file,